Publication Beamlines Strategic Pillar
Mitkova, Maria; Wolf, Kasandra; Belev, George; Ailavajhala, Mahesh; Tenne, Dmitri A. et al. (2015). X‐ray radiation induced effects in selected chalcogenide glasses and CBRAM devices based on them. Physica Status Solidi (B): Basic Research 253(6) , 1060-1068. 10.1002/pssb.201552562. BMIT-BM Materials
Izadifar, Zahra; Belev, George; Babyn, Paul; Chapman, Dean (2015). Application of analyzer based X-ray imaging technique for detection of ultrasound induced cavitation bubbles from a physical therapy unit. BioMedical Engineering Online 14(1) , 91. 10.1186/s12938-015-0085-6. BMIT-BM Materials
Wiebe, Sheldon; Samadi, Nazanin; Belev, George; Martinson, Mercedes; Bassey, Bassey et al. (2015). Small and Ultra-Small Angle X-Ray Scattering Contrast Obtained With a Synchrotron-Based Shack–Hartmann Imaging System. IEEE Transactions on Nuclear Science 62(5) , 2031-2035. 10.1109/tns.2015.2470555. BMIT-BM Materials
Samadi, Nazanin; Bassey, Bassey; Martinson, Mercedes; Belev, George; Dallin, Les et al. (2015). A phase-space beam position monitor for synchrotron radiation. Journal of Synchrotron Radiation 22(4) , 946-955. 10.1107/s1600577515007390. BMIT-BM Materials
Wiebe, Sheldon; Wysokinski, Tomasz W.; Belev, George; Miller, Denise; Webb, Adam et al. (2015). Biomedical Imaging Using Synchrotron Radiation: Experience at the Biomedical Imaging and Therapy (BMIT) Facility at the Canadian Light Source. Synchrotron Radiation News 28(5) , 16-23. 10.1080/08940886.2015.1080065. BMIT-BM, BMIT-ID Materials
Gagnon, Kenneth B.; Caine, Sally; Samadi, Nazanin; Martinson, Mercedes; van der Loop, Melanie et al. (2015). Design of a mouse restraint for synchrotron-based computed tomography imaging. Journal of Synchrotron Radiation 22(5) , 1297-1300. 10.1107/s160057751501036x. BMIT-BM Materials
Martinson, Mercedes; Samadi, Nazanin; Bassey, Bassey; Gomez, Ariel; Chapman, Dean et al. (2015). Phase-preserving beam expander for biomedical X-ray imaging. Journal of Synchrotron Radiation 22(3) , 801-806. 10.1107/s1600577515004695. BMIT-BM Materials
Izadifar, Zahra; Belev, George; Izadifar, Mohammad; Izadifar, Zohreh; Chapman, Dean et al. (2014). Visualization of ultrasound induced cavitation bubbles using the synchrotron x-ray Analyzer Based Imaging technique. Physics in Medicine and Biology 59(23) , 7541-7555. 10.1088/0031-9155/59/23/7541. BMIT-BM Materials
Tonchev, D.; Kostova, I.; Okada, G.; Pashova, T.; Belev, G. et al. (2014). Samarium Doped Borophosphate Glasses and Glass-Ceramics for X-ray Radiation Sensing. NATO Science for Peace and Security Series A: Chemistry and Biology , 347-358. 10.1007/978-94-017-9697-2_36. BMIT-BM Materials
Martin, Vincent; Okada, Go; Tonchev, Dancho; Belev, George; Wysokinski, Tomasz et al. (2013). Samarium-doped oxyfluoride borophosphate glasses for x-ray dosimetry in Microbeam Radiation Therapy. Journal of Non-Crystalline Solids 377, 137-141. 10.1016/j.jnoncrysol.2012.12.015. BMIT-BM Materials
Zhu, Y; Samadi, N; Martinson, M; Bassey, B; Wei, Z et al. (2014). SpectralK-edge subtraction imaging. Physics in Medicine and Biology 59(10) , 2485-2503. 10.1088/0031-9155/59/10/2485. BMIT-BM Materials
Okada, Go; Morrell, Brian; Koughia, Cyril; Edgar, Andy; Varoy, Chris et al. (2011). Spatially resolved measurement of high doses in microbeam radiation therapy using samarium doped fluorophosphate glasses. Applied Physics Letters 99(12) , 121105. 10.1063/1.3633102. BMIT-BM Materials
M. Hunter, David; Belev, George; Kasap, Safa; J. Yaffe, Martin (2012). Measured and calculated K-fluorescence effects on the MTF of an amorphous-selenium based CCD x-ray detector. Medical Physics 39(2) , 608-622. 10.1118/1.3673957. BMIT-BM Materials
Belev, George; Okada, Go; Tonchev, Dancho; Koughia, Cyril; Varoy, Chris et al. (2011). Valency conversion of samarium ions under high dose synchrotron generated X‐ray radiation. Physica Status Solidi (C) Current Topics in Solid State Physics 8(9) , 2822-2825. 10.1002/pssc.201084103. BMIT-BM Materials
Asai, Juhachi; Wysokinski, Tomasz W.; Smith, Sheldon; Chapman, Dean (2008). Radiological considerations for POE-1 photon shutters, collimators and beam stops of the Biomedical Imaging and Therapy beamline at the Canadian Light Source. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 585(1-2) , 1-11. 10.1016/j.nima.2007.10.049. BMIT-BM, BMIT-ID Materials