Publication Beamlines Strategic Pillar
Liu; Dong; Maxwell; Dylan; Matias et al. (2012). Web applications for experimental control at CLS. In 2012 IEEE 8th International Conference on E-Science. . , 6404470 10.1109/escience.2012.6404470. BMIT Materials
Challa P; Hinebaugh J; Bazylak AA (2011). Comparison of Water Thickness Profiles of Compressed PEMFC GDLs. In ASME. International Conference on Fuel Cell Science, Engineering and Technology. . , 121-126 10.1115/FuelCell2011-54340. BMIT-BM Materials
Hinebaugh, James; Lee, Jongmin; Bazylak, Aimy (2013). Visualizing Liquid Water Evolution in a PEM Fuel Cell Using Synchrotron Radiography. ECS Transactions 50(2) , 343-352. 10.1149/05002.0343ecst. BMIT-BM Materials
Abdullah Chisti (2013). Texture Analysis of Diffraction Enhanced Synchrotron Images of Trabecular Bone at the Wrist. Supervisor: Eramian, Mark; Cooper, David. Saskatchewan, Canada: University of Saskatchewan. https://ecommons.usask.ca/handle/10388/ETD-2013-08-1194. BMIT-BM Materials
Zangen Zhu (2013). Improved compressed sensing algorithm for sparse-view CT. Supervisor: Wahid, khan; Babyn, Paul. Saskatchewan, Canada: University of Saskatchewan. https://ecommons.usask.ca/handle/10388/ETD-2013-10-1265. BMIT-BM Materials
Alagarsamy; Nagarajan (2007). Mechanical support design of analyzer for a diffraction enhanced x-ray imaging (DEI) system. Supervisor: Szyszkowski, Walerian; Chapman, L. Dean. Saskatchewan, Canada: University of Saskatchewan. https://ecommons.usask.ca/handle/10388/etd-05172007-160800. BMIT-BM Materials
Brian E. Bewer (2010). Development of an X-ray prism for a combined diffraction enhanced imaging and fluorescence imaging system. Supervisor: Chapman, Dean. Saskatchewan, Canada: University of Saskatchewan. https://ecommons.usask.ca/handle/10388/etd-10212010-105154. BMIT-BM, SYLMAND Materials
Rahman; K M Mostafijur (2013). In-situ 3D imaging of structure and failure of materials using synchrotron radiation tomography. Supervisor: Szpunar, Jerzy A. Saskatchewan, Canada: University of Saskatchewan. https://ecommons.usask.ca/handle/10388/ETD-2013-03-971. BMIT-BM Materials
Landheer; Karl; Johns; Paul C. (2012). Coherent x-ray scatter projection imaging using an array of monoenergetic pencil beams. In Proceeding SPIE. . , 83581O 10.1117/12.918666. BMIT-BM Materials
Hinebaugh, J.; Lee, J.; Bazylak, A. (2012). Visualizing Liquid Water Evolution in a PEM Fuel Cell Using Synchrotron X-ray Radiography. Journal of the Electrochemical Society 159(12) , F826-F830. 10.1149/2.054212jes. BMIT-BM Materials
Popoola; Aminat Adeola (2009). A fiducial subject pre-alignment system for the Biomedical Imaging and Therapy Beamlines at the Canadian Light Source. Supervisor: Chapman, L. Dean; Adams, Gregg P.. Saskatchewan, Canada: University of Saskatchewan. http://hdl.handle.net/10388/etd-04142009-181529. BMIT-BM Materials
Bolibruch; N.I.; Vogt; J.M.; Igarashi et al. (2011). Photodiode Calibration using an Electrical Substitution Radiometer in the Hard X-Ray Region. In Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators. Joint Accelerator Conferences Website (JACoW). , 500-502 https://accelconf.web.cern.ch/accelconf/DIPAC2011/papers/tupd83.pdf. BMIT-BM, HXMA Materials
Lee; J.; Hinebaugh; J.; Bazylak et al. (2012). The impact of an MPL on water management of an operating PEMFC using synchrotron X-ray radiography. In Proceedings of ASME. . , 205-212 10.1115/FuelCell2012-91454. BMIT-BM Materials
Anderson; D.; Warkentin; B.; Siegbahn et al. (2010). Dosimetry for Microbeam Radiation Therapy at the Canadian Light Source. In Forty-Sixth Annual Meeting of the Canadian organization of Medical Physicists and the Canadian College of Physicists in Medicine. . , 3904 https://doi.org/10.1118/1.3476189. BMIT-BM Materials
Johns; P.C.; Warkentin; B. (2010). Canadian Light Source now accepting Imaging and Therapy Users. In 2010 Canadian Organization of Medical Physicists. . , 46-47 https://www.comp-ocpm.ca/download.php?id=360. BMIT-BM Materials